A Handy-Dandy Guide to Electric Heaters
|
|
Aquatemp has manufactured tens of thousands of electric heaters, and seen and heard just about everything about the proper care and feeding of these units; and by paying a lot of attention to the details, they have acquired an excellent understanding of what can go wrong, and why. It seemed selfish to keep all of this good stuff to themselves, so they have assembled this Handy-Dandy Electric Heater Guide to share some of that knowledge. One picture is still better than a thousand words. |

|
The term "Mechanical Failure" covers everything from shipping damage to dog bite, but the most common mechanical failures in electric heaters are caused by improper handling. Destroying the Epoxy End Seal (5), and breaking or twisting the Cold Pin (10) until it breaks are the two leaders in this failure mode. Because they are so closely related we'll look at them together . WHAT HAPPENS? Any form of rough handling can put pressure on the part of the heater that sticks out the most - the Electrical Terminal (1), which is welded to the Cold Pin (10), which in turn passes through the Epoxy End Seal (6) to get to the Heating Coil (13) inside of the element. If the Electrical Terminal (1) is broken away from the Cold Pin (10) there is obviously no way to connect electrical wires to the heater, and it becomes a throw-away.
If you don't know what caused the GFCI to turn the power off, you might start investigating "nuisance tripping". Without the GFCI there will eventually be arcs, sparks and possibly even flames. HOW CAN THIS BE PREVENTED? Moisture may get inside of the element when it is off. Part of the cooling off process is to suck in any surrounding air through any crack. Then, the next time the element is energized, the moisture in the element may provide a path for current to flow, and the GFCI will trip. But, a BIG but, the heater may have been on just long enough to produce enough heat to drive that moisture out of there. You come along and reset the GFCI and the heater will come back on again. Drive ya nutty, as they say. Check that Epoxy End Seal carefully. Never bend, push, pull or twist the Electrical Terminal (1). Always use two wrenches to tighten or loosen the Terminal Nut (2) . One wrench holding the Terminal Hex (4) to keep it from turning, and one on the Terminal Nut (2) to do the tightening or loosening. The trick to analyzing this failure is to carefully examine the Epoxy End Seal. Signs of severe fracture or chipping are an almost sure bet that the End Seal is no longer able to do its job to seal. If the heater has been acting strangely, erratic, sometimes working fine and other times tripping the GFCI, carefully examine the Epoxy End Seal. THE NOISY HEATERS - HUMS, VIBRATIONS, SQUEALS, TWITTERS, SHRIEKS, SCREAMS, RATTLES, WHISTLES, TWEETS, & CHIRPS Rarely, maybe never, is the element itself at fault when noise is reported in a heater, even though it is the element that is usually making the noise. The huge amount of water moving rapidly past the element can set up some wild vibration patterns as it twists and turns through the heater. Usually it is simply a matter of re-aligning the element by a bit of gentle bending to move it away from the heater housing, or tying the noisy part down with a clip or wire made for the purpose. |
|
SETTING THE STAGE In normal operation the heaters that we deal with daily in hot tubs and spa operate at temperatures only a few degrees above the temperature of the water that is flowing past them. If the thermostat in a spa is set to maintain the water at 102º, for example, the temperature of the Incoloy Outer Sheath (12) will be about 110º. The water flowing past the element is carrying the heat away just about as fast as the element can produce it. WHAT GOES WRONG?
The results will be the same. The Incoloy Outer Sheath (12) temperature will rapidly rise - 200º - 500º - 1,000º - 1,500º in a matter of just a minute or two. This is approaching the melting point of the Sheath and it will get there quickly if it isn't turned off by some safety device like a high-limit switch. The failure can show up in several different ways;
WHY? Taking a look at a few of the things learned from a lot of field experience plus a ton of hours in the engineering lab: HIGH LIMIT PROTECTION - the primary job of the High Limit Switch in the finished product is to prevent scalding water from ever reaching the people using the product. Sure, the Thermostat should shut the heater off long before the point at which the High Limit Switch is needed, but Thermostats, like everything else, fail. Will the High Limit do its job? It hasn't had to operate for months or years. Is it ready? Is it in the right place to do the job? If the High Limit is not sensing the water temperature close to the element, and the pump suddenly quits, it's dry fire time in just a minute or two. The element will boil the water in the heater housing and create its own "dry" condition. Following that, the service technician arrives and finds the heater assembly full of water again, and claims it couldn't have been a dry fire. Check that High Limit. FLOW / PRESSURE SWITCHES - various types of devices are used to detect whether there is any water flowing through the heater assembly. Unfortunately, when these things fail, they generally fail in the closed position and there is no indication that they are not doing their job. In most cases a spa system will work just fine with a stuck pressure or flow switch, until there is a need for it. If a full-scale dry-fire destroys the flow or pressure switch along with the element, it's impossible to determine which went first; but one thing is certain, the heater was doing its job. It isn't very smart, it just makes heat. |
|
CORROSION - the Bad Guy
We think it's a safe bet to say that one of the major causes of heater failure has always been corrosion. Given any chance at all, this demon will destroy a heater element or, in many cases, the entire heater. The corrosion we come across in our industry, particularly in spa equipment, comes in many varieties, each with it's own name and characteristics. We're faced with galvanic corrosion, chemical pitting, intergranular corrosion, stress corrosion cracking, corrosion fatigue and electrochemical corrosion. There's even have a strain of iron eating bacteria, Ferrobscillus in the Siderocapsaceae family, to contend with. WHAT CAUSES ALL THIS? A full discussion of the chemistry and electrochemistry involved with this pretty complex subject is beyond the intent of this Guide. It's much easier to describe what doesn't cause it than to attempt to explain all the chemistry that does. Consider this, if all those spas out there were filled with clean, pure water, and no one ever added any chemicals to them, the word corrosion would soon leave our vocabulary, Unfortunately, that's not going to happen, and all those spas are going to continue being filled with water of every type, from the Cascade Mountain's rain water to big-city sludge. A DEADLY SOUP
LOW pH ! If we had to pick the worst offender in the corrosion list, it would definitely be LOW pH, because, as we all learned long ago, when a test sample of the water shows a LOW pH (below 7.0), it indicates the water is ACIDIC. Remember now, this is not just saying that there is ACID in the water, it says that the water has become an ACID. It doesn't matter at all what kind of ACID caused this to happen; hypochlorous, hydrochloric, hypobramous, muriatic or whatever, when the water becomes an ACID it becomes a starving, hungry, corrosive beast looking for lunch. ACIDS will corrode and eat away almost any metal in their path in order to satisfy that hunger. An element or heater corroded because the water has a LOW pH is easy to spot. It has pieces eaten away from its surface. Gone, disappeared, departed. It looks like the craters of the moon. And people are putting their bodies in there! SCALE / CALCIFICATION
MOPE UGLINESS Bad-chemistry corrosion can show up where the element sheath is brazed to the bulkhead fitting, or welded to a mounting plate. Even though all of the parts are "stainless steel", and selected just for this purpose, the ingredients (mostly iron, chromium, nickel and molybdenum) in the steel must vary. The mix has to be different for parts like the Bulkhead Fitting (8) that needs to be machined, versus the thin, high temp Incoloy Outer Sheath (12) that must be bent and formed. Very special welding techniques are used at these joints to make sure that no impurities are left behind that might corrode. But, if the water gets bad enough, you may see corrosion at these weld points. It can range anywhere from a rust-like deposit to cracks and fissures in the metal. At its worst it can result in "corrosion fatigue," causing the Bulkhead Fitting to break away from the Outer Sheath. This corrosion is bad stuff. AND THEN, THERE'S THE IRON EATER A slippery, brownish coating on the inside wall of a spa may not, be any form of algae, but can be the effects of an "iron eating bacteria" that is gnawing away at the heater. This one is easy to correct. The water simply needs some sanitizer. chlorine, bromine or ozone. A "shock" treatment would probably be in order here, a drain and refill if it won't go away. WHAT'S THE BOTTOM LINE ON CORROSION? Corrosion of the metal in a hot tub or spa heater happens when the water becomes corrosive because somebody makes mistakes with its chemistry. There are more than 2,000,000 spas in the USA alone that have never shown any signs of corrosion, some more than twenty years old. Their owners follow the instructions of the professionals at their local pool/spa store, and maintain a good sanitizer level along with a non-corrosive pH level, and monitor their Total Alkalinity, Calcium Hardness and Total Dissolved Solids for a good water balance. They do not. "Throw in a little of this or a little of that." That's like signing a Pledge Of Corrosion. |
|
DO THEY EVER JUST "BURN OUT"? It's correct to say that the only "natural", like in "died of natural causes," electrical failure that a resistance-wire heater ever suffers is when the Heating Coil (11) breaks, causing an OPEN in the circuit. It's exactly the same as a light bulb burning out . It just gets tired of the tremendous trauma it goes through each time the power is applied. Picture it, it goes from cold to very, very hot in less than 1/10th of a second. It opens its door to see who's knocking and a thousand billion billion electrons (that's 21 zeros!) rush in during the first second. Because of the careful selection of components in the Heating Coil, this sort of failure is actually quite rare. (Have you every seen a light bulb burn out while it was on? Probably never. They always burn out just as you turn them on. That's "turn-on trauma".) However, it can be brought on more quickly by switching the heater on and off rapidly. This can happen with a defective control, such as a chattering contractor or thermostat, for example. Be very suspicious if a replacement heater burns out quickly. Watch for this. Another suspect in an OPEN situation is a reduced water flow that causes the element to operate at a much higher temperature than normal, but not high enough to cause a dry-fire condition. There may be no signs of the problem on the outside of the element. It just got tired of working too hard. |
|
THEY'RE SIMPLE - REALLY Of any piece of equipment you might find on a spa or hot tub today, the electric heater is probably the most simple. We're not talking here about the controls, just the heater itself. What makes it simple is that it is a straight resistive device. It doesn't have any coils like motors and transformers, giving them inductive characteristics,iron eating bacteria and it isn't anything at all like a solid state, printed circuit board mounted, micro-processor based control system. With heaters, the electrical is plain-Jane. THE IMPORTANT NUMBERS You can learn just about all there is to know about an electric heater by applying a little knowledge and a smidgen of easy math, along with a decent test meter. We'll start with the basis numbers:
The math part is kept simple by using our Handy-Dandy Decoder King, shown to the right. Let's say you want to figure the amps rating of a heater marked 240 volts & 5500 watts. Use W/V : that would be 5500 divided by 240, and the answer is 22.9 amps. The next three are measured with a meter at an operating heater:
USING THE NUMBERS All that follows applies to all electric heaters. The task is simple; to determine if the heater is producing heat (watts), and then make sure that it is safe. First, measure and compare the voltage at the heater terminals with the voltage at the panel board, receptacle or other power source. don't blame the heater for poor performance if this Measured Voltage is more than 10% below the heater's Rated Voltage. (Do the math, to see how quickly the watts drop as volts drop. ) If the Measured Voltage was much different than the Rated Voltage, you'll have to re-figure the Calculated Amps using V/O. (You can't use W/V, because you're not sure what the wattage is anymore.) Then, with power still on, put your clamp-on ammeter around ONE of the heater wires - either one, but only one. You're now reading Measured Amps, which should match the Calculated Amps number, within 10%. Turn OFF all power, then DISCONNECT BOTH WIRES from the heater terminals. Set the meter to the Ohm's scale and take the following readings at the element terminals:
That's it. You now know all there is to know about the electric stuff in the heater. You can now re-calculate the wattage using the voltage, amps and ohms numbers you have measured, confident in your knowledge. |
||||||||||||||
|
A good test meter is a must if we are to learn what's going on in the electric heart of that heater. Take full advantage of today's technology and check out the latest units that combine the digital volt/ohm meter with a clamp-on ammeter. It's like they knew about electric heaters when they designed these guys. Check out B&K Precision's 330 8 340; A.W. Sperry's DSA-2007, and others by Radio Shack, Fluke and Scope. All are available in the $80 - $100 range. |

|
If you have any questions, please feel free |